Adiradh offers the Acoustic Imaging Camera MPAC208-IECEx for safe and reliable ultrasonic inspection in hazardous industrial environments. Moreover, the camera detects gas leaks, partial discharge, and mechanical faults without interrupting normal operations. In addition, the IECEx-certified design allows safe use in Class 2 explosive atmospheres. Furthermore, the 208-channel MEMS microphone array captures ultrasonic signals from 2 kHz to 100 kHz with high sensitivity. Therefore, technicians can identify even small leaks and hidden equipment defects quickly. Also, the integrated 13 MP optical camera displays real-time acoustic overlays for accurate fault localization. Consequently, inspections become faster and more efficient. In addition, the lightweight construction and long battery life support extended field operation. Furthermore, the IP54-rated housing provides dependable protection in demanding industrial conditions. Finally, the MPAC208-IECEx supports predictive maintenance, improves equipment reliability, reduces energy losses, enhances worker safety, and delivers accurate acoustic imaging for oil and gas, chemical plants, utilities, manufacturing, and hazardous industrial facilities.

The Acoustic Imaging Camera MPAC208-IECEx is a professional ultrasonic inspection camera developed for industrial maintenance in hazardous locations. It combines a 208-channel MEMS microphone array with a 13 MP optical camera to generate real-time acoustic images that clearly identify ultrasonic sound sources. Moreover, the IECEx certification enables safe operation in Class 2 explosive atmospheres without compromising inspection performance. In addition, the camera supports Gas Leak Mode, Partial Discharge Mode, and Mechanical Mode for comprehensive equipment assessment. Furthermore, users can detect compressed air leaks, gas leaks, electrical discharge, bearing wear, valve leakage, cavitation, and vibration-related defects using a single portable instrument. Therefore, maintenance teams can perform inspections efficiently while maintaining operational safety. Also, the camera offers a detection range of up to 200 meters for stand-off inspections in substations, process plants, and industrial facilities. Consequently, the MPAC208-IECEx improves predictive maintenance, equipment reliability, and operational efficiency.

The Acoustic Imaging Camera MPAC208-IECEx integrates a 208-channel MEMS (Micro-Electromechanical System) microphone array operating across 2 kHz to 100 kHz for high-sensitivity ultrasonic detection. Moreover, the instrument utilizes real-time acoustic beamforming to visualize ultrasonic emissions with high accuracy. In addition, the integrated 13 MP optical imaging sensor overlays acoustic information onto live visual images for precise fault localization. Furthermore, the 8-inch capacitive touchscreen provides clear acoustic visualization and intuitive operation. The Gas Leak Mode automatically estimates leak rate, leak distance, and energy loss. Meanwhile, the Partial Discharge Mode performs PRPD (Phase Resolved Partial Discharge) analysis for identifying discharge activity in high-voltage systems. Also, the Mechanical Mode detects bearing defects, valve leakage, cavitation, and vibration-related mechanical deterioration through ultrasonic signatures. The Focus function suppresses background noise, while SoundScan™ directional guidance assists in locating off-screen sound sources. The optional MPAC-V verification accessory validates frequency response, SPL accuracy, and microphone calibration.
Datasheet for Acoustic Imaging Camera MPAC208-IECEx
User manual for Acoustic Imaging Camera MPAC208-IECEx
The Acoustic Imaging Camera MPAC208-IECEx combines advanced ultrasonic sensing technology with certified hazardous-area protection for dependable industrial inspections. Moreover, the high-density MEMS microphone array delivers accurate acoustic localization over a broad ultrasonic frequency range. In addition, acoustic beamforming produces real-time visualization that speeds fault detection. Furthermore, the Focus function reduces background noise for reliable inspection in noisy industrial environments. Therefore, operators can isolate target sound sources with greater confidence. Also, SoundScan™ directional guidance helps locate leaks outside the visible camera frame. Consequently, inspection time is reduced while diagnostic accuracy improves. In addition, the optional thermal imaging module enables simultaneous acoustic and thermal analysis for enhanced root cause assessment. Furthermore, interchangeable smart batteries provide up to 10 hours of continuous operation, while the lightweight 1.4 kg design supports comfortable field use. Finally, IECEx certification allows safe inspection in Class 2 explosive atmospheres, supporting predictive maintenance, operational safety, equipment reliability, and reduced unplanned downtime.
Adiradh Energy offers Acoustic Imaging Camera MPAC208-IECEx in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities
![]()
2025 - Industry. All Rights Reserved.