Battery testing BTS 200

Adiradh offers the Battery Test System BTS 200 from ISA, designed for battery capacity testing and maintenance. This battery testing equipment uses the discharge method to check battery performance and available capacity. It measures battery voltage, discharge current and discharged ampere-hours during testing. Moreover, the BTS 200 supports discharge currents up to 1300 A when connected to external ELU 200 load units. Therefore, it is suitable for testing battery banks used in power plants, substations and industrial facilities. In addition, its graphical display shows test values, discharge curves and results. The internal memory also helps store test data for later review. Furthermore, operators can use a current clamp or external shunt for additional current measurement. Its portable design includes handles and wheels for easy movement. Consequently, the BTS 200 supports battery testing and maintenance in electrical utilities and industrial installations.

Battery testing BTS 200

Overview

The ISA BTS 200 is a high-power battery test system developed to measure battery capacity through controlled discharge testing. It monitors battery voltage and discharge current while recording the discharged capacity in ampere-hours. Moreover, it supports different battery types and testing requirements. The system provides a maximum discharge current of up to 130 A through its internal load, depending on the battery voltage. In addition, it can work with up to nine external ELU 200 load units to increase the discharge current up to 1300 A. The graphical display shows battery voltage, discharge current, test duration and discharge curves. Furthermore, the internal memory stores test information for later review. Therefore, the BTS 200 helps maintenance teams assess battery capacity and review battery performance.


Datasheet for Battery testing BTS 200

Download


About Product

The Battery Test System BTS 200 uses the battery discharge method to measure the capacity of new and used battery banks. During testing, the instrument applies a controlled load and monitors the battery voltage and discharge current. Moreover, it records the discharged capacity in ampere-hours and displays the test duration. The operator can set a minimum voltage threshold to stop the discharge automatically when the battery reaches the selected limit. In addition, the system supports different discharge modes and test profiles. It can also connect to external ELU 200 load units to increase the available discharge current. Furthermore, an optional current clamp or external shunt allows measurement of additional current. The graphical display presents test parameters and discharge curves. Consequently, operators can review the test results and assess battery performance.

Technology & Benefits

The BTS 200 uses controlled battery discharge technology to assess battery capacity and performance. During the test, it applies a selected load to the battery and measures the resulting voltage and current. As a result, operators can review the battery’s discharge behaviour and available capacity. Moreover, the instrument records discharged ampere-hours and test duration. It also displays discharge curves for easier result analysis. The system supports external ELU 200 load units when higher discharge current is required. Furthermore, up to nine external load units can be connected to achieve discharge currents up to 1300 A. The current clamp and shunt options also support additional current measurement. In addition, the internal memory helps retain test information. Therefore, the BTS 200 supports battery maintenance, capacity assessment and routine testing in industrial and utility installations.

Key Features

  • High-power battery capacity test system.
  • Battery voltage measurement.
  • Battery discharge current measurement.
  • Battery capacity testing through the discharge method.
  • Discharge current up to 130 A through the internal load, depending on battery voltage.
  • Discharge current up to 1300 A with external ELU 200 loads.
  • Supports connection of up to nine external ELU 200 load units.
  • Graphical display for test parameters and results.
  • Battery discharge curve display.
  • Internal memory for storing test data.
  • Shunt-based additional current measurement.
  • Optional current clamp measurement.
  • Adjustable minimum battery voltage threshold.
  • Automatic test stop at the selected voltage limit.
  • Different battery discharge modes.
  • Portable design with handles and wheels.
  • Suitable for different types of batteries.

Applications

  • Battery capacity testing.
  • Stationary battery bank testing.
  • Industrial battery testing.
  • Power plant battery maintenance.
  • Substation battery testing.
  • UPS battery capacity testing.
  • Backup power battery testing.
  • Battery discharge testing.
  • Battery performance assessment.
  • Electrical utility battery maintenance.
  • Power generation facility battery testing.
  • Industrial battery maintenance.
  • Battery testing in electrical substations.
  • Testing of new and used battery banks.

Advantages

  • Measures battery voltage and discharge current.
  • Helps assess battery capacity through discharge testing.
  • Supports different battery types.
  • Allows high-current discharge testing with external loads.
  • Supports up to nine ELU 200 external load units.
  • Displays test values and discharge curves.
  • Internal memory helps store test information.
  • Supports additional current measurement through a clamp or shunt.
  • Automatic test stop at the selected minimum voltage.
  • Portable design supports movement between test locations.
  • Helps maintenance teams review battery performance.
  • Suitable for industrial and electrical utility applications.

Adiradh Energy offers Battery testing BTS 200 in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities