Capacitance and Tan delta kit -12KV Insulation Diagnostic system

Adiradh Energy offers  Megger make  fully automatic capacitance and tan delta kit Model Delta 4000 Series ,Resonating inductor ,High precision  C and  DF Measurement Model CDAX 605 supply all over India .Tan Delta tests are carried out for Transformer Bushing and for the Transformer Winding. Transformer Bushing Tan Delta system is similar to the CT Tan Delta Test .Tan delta  is the Ratio of the Resistive Component to the Capacitive Component of the Leakage Current. It should be minimum and ideally equal to zero.

Capacitance and Tan Delta Kit 

Capacitance and Tan delta test kit  Delta4110 in India  is fully automatic designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters, and rotating machinery. Measurements include voltage, output current up to 300 mA, power (loss), tan delta, inductance, power factor and capacitance. Tan delta 4110 accurate measurement results under high noise conditions as tested up to 765 kV substations. Temperature correction allows the user to estimate the actual temperature dependence of the test object by measuring capacitance and tan delta measurement over a frequency range from 1 HZ to 500 HZ and automatic voltage dependence detection.

Capacitance and tan Delta test system Megger DELTA4110  is designed to provide a comprehensive AC insulation diagnostic test. The high power variable frequency design generates its own test signal independent of line frequency quality and the hardware design uses the latest technology available for digital filtering of the response signal. As a result, Automatic capacitance and tan-delta test set  DELTA Series produces reliable results and stable readings in the shortest time with the highest accuracy, even in high interference substations. Adiradh Energy  offering Tan delta test kit best price  in Hyderabad,Bangalore ,Bhubaneswar,Chennai,Kochi, Pune, Visakhaparnam ,Coimbatore,Delhi, Mumbai,Noida,Kolkata,Ahmadabad,Hubli and Gurgaon. Delta4000  Series operates with PowerDB software for automatic testing and reporting or with Delta Control software for real-time manual testing

12 kV Insulation Diagnostic System  Delta40o0 series has two configurations

Tan delta system Features

  • Power factor test set
  • Automatic and manual operation
  • Accurate measurement results under high noise conditions as tested to 765 kV substations
  • Lightweight, rugged two-piece design
  • High noise suppression and advanced signal acquisition circuitry can handle up to 15 mA interference current or a signal to noise ratio of up to 1:20 resulting in extremely accurate and clean measurements even in the most severe conditions
  • Individual Temperature Correction (ITC) allows the user to estimate the actual temperature dependence of the test object by measuring tan delta over a frequency range. Mathematically calculating accurate individual temperature correction results in a more accurate measurement of the insulating material’s condition,eliminates the need for temperature correction tables
  • Ability to perform wide range DFR for diagnostic (1-500Hz) testing of transformer, bushings
  • Voltage dependence detection (VDD ) to automatically warn if test object shows signs of power factor voltage dependence
Capacitance and Tan delta test kit

Tan delta test system DELTA4110 in India

 

capacitance and tan delta test of transformer

Fully automatic capacitance and tan delta -Delta4310

12kV Capacitance and Tan delta

Power Factor Test Set Megger DELTA4310

12 kV Insulation Diagnostics HV connection

HV Cable connection for Capacitance and Tan delta

Tan delta applications: Power transformers , Distribution transformers, Instrument transformers,  Rotating machines, Oil insulationn Bushings, Cables, Capacitors, Circuit breakers, Surge arresters

 

Capacitance and Tan delta test capabilities : Power factor, Dissipation factor (tan∂),  Excitation current, Power factor tip-up, Watts loss, Inductance, Capacitance, Voltage, Current ,Turns ratio.

Adiradh Energy supply  Tan delta kits,Capacitance and  tan delta  systems ,12KV Insulation Diagnostic system ,Delta4110,Delta4000 series ,Delta4310A,in India;Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara;Ahmedabad;Chandigarh;Chandigarh;Tata Nagar; Raipur; Rudrapur;; Durgapur; Kharagpur;Raigarh;Bhilai;Angul; Haldia;Jabalpur;Indore;Jamshedpur; Rajahmundry; Bokaro Steel City;salem;kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City ; Nashik;Haridwar;Mathura;Aurangabad ; Bhubaneswa,Gurgaon and other cities

Brochure for Capacitance and Tan delta Delta4000 Series-Delta4110-Delta4310A

DELTA4000 12 kV insulation diagnostic system application guide  Click  on 

1-500Hz Narrow Band Dielectric Frequency Response  for Tan delta Click  on 

wide ranging frequency capability of the Delta4000 Click  on

Capacitance and Tan Delta Megger 4110 User Training guide  Click  on

Predictive diagnostic testing of electrical apparatus including transformers Click  on
DELTA4110 Insulation Diagnostic System scope of supply 
DELTA4100 control unit
DELTA4010 HV unit
High voltage lead: 21 m (70 ft) double shielded 30012H-11
Measurement lead  color-coded red, 21 m (70 ft) 25572-1
Measurement lead color-coded blue, 21 m (70 ft) 25572-2
Ground lead: 9 m (30 ft) 2002-131
Input power cable 16A EU 17032-29
Input power cable 16A US 17032-28
Input power cable 16A UK 17032-30
Safety hand switch,Interlock #1, 21 m (70 ft) 1001-850
Safety foot interlock, 3m (10 ft) 1001-852
HV unit power cable, 1 m (3 ft) 2002-132
HV unit control cable, 1 m (3 ft) 2002-133
Ground lead interconnect cable, 1 m (3 ft) 2002-134
USB cable, 2 m (7 ft)
CA-USBEthernet cable,
CAT 5, 2 m (7 ft) 36798
Lead Bag for HV cable 2001-507
Lead Bag for other cables/accessories 2005-265
Software DELTA manual control 1001-981
PowerDB Lite software
Specifications of Capacitance and Tan Delta  DELTA4000 Series 
Input Power
90 – 264 V 45 – 66 Hz16 A maxNo loss in performance when used with portable generator.
Output Voltage :0 to 12 kV, continuously adjustable
Test Frequency Range45-70 Hz (12 kV)15-400 Hz (4 kV)1-505 Hz (250V)0.0001 Hz maximum resolution
Output Power3.6 kVA
Output Current
300 mA (4 minutes)
200 mA (30 minutes)
100 mA (continuous)
The power supply capacity can be expanded to 4 A at 12 kV using the optional Resonating Inductor, (Cat. No. 670600-1).
Measuring Ranges
Voltage:25 V to 12 kV, 1 V resolution
Current0: to 5 Amps, 0.1 μA maximum resolution. The measurement can be corrected to either 2.5 kV or 10 kV equivalents.
Capacitance: 0 to 100 μF, 0.01 pF maximum resolutionInductance: 6 H to 10 MH, 0.1 mH maximum resolution
Power factor: 0-100% (0-1), 0.001% maximum resolution
Dissipation factor: 0-100 (0-10,000%), 0.001% maximum resolution
Watt Loss0 to 2 kW, actual power, 0 to 100 kW when corrected to 10 kV equivalent. 0.1 mW maximum resolution. The measurement can be corrected to either 2.5 kV or 10 kV equivalents.
Temperature Correction
Individual temperature correction from 5°C to 50°C insulation test temperature to 20°C reference
Standard tables
As by international standards and manufacturers’ data
Accuracy
Voltage ±(1% of reading)Current ±(1% of reading)Capacitance ±(0.5% of reading + 1 pF)Inductance ±(0.5% of reading + 1 mH)Power Factor and Dissipation Factor ±(0.5% of reading + 0.02%)Watt Loss ±(1% of reading + 1mW)Frequency ±0.005% of reading
Noise Immunity
Electrostatic
15mA induced noise into any test lead with no loss of measurement accuracy at maximum interference to specimen current of 20:1
Electromagnetic
500 μT, at 50/60 Hz in any direction
Measurement
UST: Ungrounded Specimen TestingGST: Grounded Specimen Testing
PC Requirements
DELTA4110
Operating system: Windows 7, WIndows 8 and Windows 10Processor: Min Pentium 1 GHzMemory: Min 1024 Mb RAMHard drive: Min 2 Gb availableInterface: USB and Ethernet
DELTA4310A
Internal PC (provided)
DELTA4310A Provided Hardware
Touchscreen Display (ruggedized for field use)Size: 300 mm (12 in.)Resolution: 1024 x 768 (XGA)Luminance: 1600 nitsCoating: anti-glareBacklight: LEDTechnology: 4-wire resistive touchscreenMemory: 32 Gigabits (SSD)
Controls & Communication
Built-in touchscreen, 2 only USB 2.0 ports and 1 only Ethernet interface (10/100 Mbps) provided for data export, built-in printer as well as OnBoard computer remote control of the Megger TTR3XX, MTO3XX, MLR10, MWA3XX and S1/MIT series insulation testers.
Environment
Temperature
Operating: -20 to +55° C (-4 to +131° F)Storage: -50 to +70° C (-58 to +158° F)
Relative humidity
Operating and Storage: 0 to 95% non-condensing

Detailed description of the Megger Delta4000’s general hardware and optional accessories.

 

DELTA4000 transformer test set helps to ensure that insulation power factor tests are completed safely and efficiently

How to connect the Megger Delta4000 to a transformer to perform a power factor test

 

How to Perform an Excitation Current Test using DELTA4000 Series 

Capacitance and Tan delta 4000 series  Comply with  Standards
Safety
IEC / ANSI 61010-1:2001
Shock and vibration
IEC 68-2-31, first edition, drop and topple (push over)
IEC 68-2-31, second edition, free fall
ISTA 2A
EMC
FCC 47 CFR Part 15 Class A Emissions requirements (USA)
(FCC Subpart B of Part 15 Class A)
EN 55011:1998/A1:1999/A2:2002 Group 1 Class A ISM Emissions
requirements (EUROPE)
AS/NZS CISPR 11:2004 Class A ISM Emissions requirements
(Australia)
EN 61326:1997/A1:1998/A2:2001/A3:2003
IEC/EN 61000-4-2/3/4/5/6/8/11
IEC/EN 61000-6-2
Test Equipment Specifications Met: IEC/EN 61000-6-4;
IEC 801-2(1984) Electrostatic Discharge; ANSI/IEEE C37.90.1 Surge Withstand Capability

 

Resonating inductor 

Resonating inductor  is an accessory for use with the semi-automatic 12 kV extended-range capacitance and dissipation factor equipment , or the automated insulation power factor unit (DELTA series) Capable of tuning capacitances up to 1µF at 10 kV.

Resonating-inductor

 

Adiradh Energy offers  resonating inductor in India;Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara;Ahmedabad; Chandigarh;Chandigarh;Tata Nagar; Raipur; Rudrapur;; Durgapur; Kharagpur;Raigarh;Bhilai;Angul; Haldia;Jabalpur;Indore;Jamshedpur; Rajahmundry; Bokaro Steel City;salem;kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City ; Nashik;Haridwar;Mathura;Aurangabad ; Bhubaneswar,Gurgaon and other cities 

Brochure for Resonating Inductor

Download

High precision  C and  DF Measurement equipment 

CDAX 605 is a capacitance and dissipation factor measurement set to be used with an external power source/generator. It is a precision instrument using a combination of bridge and direct (vector) measurements and is capable of measuring capacitive, resistive and inductive loads.

 CDAX 605 HIGH-PRECISION C AND DF MEASUREMENT INSTRUMENT

HIGH-PRECISION C AND DF MEASUREMENT INSTRUMENT

Adiradh Energy offers  high precision C and DF measurement equipment ,CDAX 605 in India;Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad;Chandigarh;Chandigarh;Tata Nagar; Raipur; Rudrapur;; Durgapur; Kharagpur;Raigarh;Bhilai;Angul; Haldia;Jabalpur;Indore;Jamshedpur; Rajahmundry; Bokaro Steel City;salem;kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City ; Nashik;Haridwar;Mathura;Aurangabad;Bhubaneswar,Gurgaon and other cities

Brochure for High-precision C and DF measurement instrument CDAX605