Product Details

Home | Product Details

InsuLogix® G2 acetylene, hydrogen, and moisture monitor

Adiradh offers the InsuLogix® G2 acetylene, hydrogen, and moisture monitor for continuous transformer dissolved gas analysis and condition assessment. Moreover, it enables real-time monitoring of acetylene (C₂H₂), hydrogen (H₂), and moisture in oil, which are key fault indicators. Therefore, utilities can detect arcing, partial discharge, and thermal faults at an early stage. In addition, the monitor provides accurate online data without manual oil sampling. Furthermore, it supports predictive maintenance strategies and improves asset reliability. Consequently, operators can reduce unplanned outages and maintenance costs. Also, the system integrates easily with substation communication networks for remote supervision. As a result, maintenance teams receive timely alerts and actionable diagnostics. Thus, the InsuLogix® G2 acetylene, hydrogen, and moisture monitor strengthens transformer fleet management. Finally, it helps ensure safe operation, longer insulation life, and improved operational performance in critical power infrastructure.

Overview

The InsuLogix® G2 acetylene, hydrogen, and moisture monitor is an online dissolved gas monitoring solution designed for power transformers and critical oil-filled assets. It continuously measures acetylene, hydrogen, and moisture levels directly from transformer oil. Therefore, it enables fast identification of incipient electrical and thermal faults. Moreover, acetylene detection supports early recognition of arcing events, while hydrogen monitoring indicates partial discharge and overheating. In addition, moisture measurement helps assess insulation aging and dielectric strength. The system provides digital data output for SCADA and remote asset management platforms. Furthermore, it features robust enclosure design suitable for substation environments. Consequently, it ensures stable operation under varying load and temperature conditions. Also, automated data logging simplifies trend analysis. As a result, asset managers gain clear insights into transformer health. Thus, the monitor supports data-driven maintenance planning and risk reduction across transmission and distribution networks.

About Product

The InsuLogix® G2 acetylene, hydrogen, and moisture monitor uses advanced dissolved gas analysis (DGA) principles for online transformer diagnostics. It incorporates selective gas sensing technology for precise quantification of C₂H₂ and H₂ concentrations in transformer oil. Moreover, it includes a moisture-in-oil sensor based on relative saturation and ppm measurement. The system performs continuous oil sampling through an integrated oil circulation mechanism. Therefore, it delivers stable and repeatable readings under dynamic load conditions. In addition, the device supports digital communication protocols for SCADA integration and remote data acquisition. Furthermore, it provides configurable alarm thresholds for fault severity classification. Consequently, maintenance teams can respond to abnormal gas generation promptly. Also, built-in temperature compensation enhances measurement accuracy. As a result, the monitor ensures reliable long-term operation in high-voltage substations. Thus, it forms a critical component of transformer condition monitoring and predictive maintenance programs.

Datasheet for InsuLogix® G2

Download

User manual for InsuLogix® G2

Download

Technology & Benefits

The InsuLogix® G2 acetylene, hydrogen, and moisture monitor applies advanced sensor technology for selective dissolved gas detection. Moreover, its acetylene channel enables rapid identification of arcing faults. Therefore, operators can isolate developing internal faults before severe damage occurs. In addition, hydrogen monitoring supports early detection of partial discharge and thermal decomposition. Furthermore, continuous moisture measurement helps maintain optimal dielectric strength of transformer insulation. Consequently, asset life can be extended through timely corrective action. Also, real-time data transmission improves visibility across distributed substations. As a result, condition-based maintenance replaces routine time-based inspection. Thus, operational efficiency increases while maintenance costs decrease. In addition, automated alarms reduce response time during abnormal events. Therefore, outage risk is minimized and system reliability improves. Finally, accurate trend analysis supports informed decision-making for asset replacement and load management planning.

Key Features

  • Continuous online monitoring of acetylene (C₂H₂), hydrogen (H₂), and moisture in oil

  • Early detection of arcing, partial discharge, and thermal faults

  • Integrated moisture-in-oil measurement (ppm and relative saturation)

  • Advanced dissolved gas analysis (DGA) sensing technology

  • Digital communication for SCADA integration

  • Configurable alarm thresholds and event alerts

  • Automated data logging and trend analysis support

  • Temperature compensation for improved accuracy

  • Robust enclosure for substation installation

Applications

  • Power transformer online condition monitoring

  • Transmission and distribution substations

  • Generator step-up transformers

  • Critical industrial transformers

  • Renewable energy substations

  • Asset health and predictive maintenance programs

Advantages

  • Reduces unplanned transformer outages

  • Enables early fault detection and diagnosis

  • Improves insulation life through moisture control

  • Supports condition-based maintenance strategy

  • Minimizes maintenance cost and downtime

  • Enhances asset reliability and operational safety

  • Provides real-time remote monitoring capability

 

Adiradh Energy offers InsuLogix® G2 acetylene, hydrogen, and moisture monitor in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities