Product Details

Home | Product Details

Primary Current Injection Test System INGVAR

Adiradh offers the Megger INGVAR Primary Current Injection Test System for testing electrical protection systems, circuit breakers and current transformers. It provides high AC current injection of up to 5000 A in parallel configuration. Therefore, it is suitable for substation testing, switchgear maintenance and industrial electrical testing. Moreover, the system combines a control unit and a current unit for field use. This two-unit design makes transport and setup easier. In addition, its built-in measurement system displays current, voltage and time. It also measures current transformer turns ratio, impedance, power factor and phase angle. Furthermore, the unique I/30 function helps users preset the required test current at a lower level. As a result, it helps reduce heating of the test object before the main test. The Megger INGVAR is useful for electrical commissioning, maintenance and primary injection testing.

Overview

The Megger INGVAR is a primary current injection test system designed for electrical testing and commissioning. It delivers up to 5000 A in parallel configuration for short-duration tests. Therefore, it supports high-current testing of circuit breakers, current transformers and protection systems. The system consists of a control unit and a current unit. Moreover, each unit weighs approximately 20 kg, which helps simplify transportation and handling. Its control unit includes digital current, voltage and time measurements. In addition, a second measurement channel allows users to measure another current or voltage. The system also calculates CT turns ratio, impedance, power, power factor and phase angle. Furthermore, its fast-acting hold function captures short-duration readings. Consequently, engineers can use the recorded values to assess equipment performance during testing.

About Product

The Megger INGVAR Primary Current Injection Test System consists of two main units connected through dedicated cables. The current unit generates high AC injection current through its transformer arrangement. Moreover, users can configure the system in series or parallel mode to meet different current and load voltage requirements. In parallel configuration, the maximum output reaches 5000 A for up to 2 seconds. The control unit includes digital ammeters, a voltmeter and an electronic timer. In addition, its measurement section supports AC and DC RMS measurements. It can calculate current transformer (CT) turns ratio, impedance, resistance, reactance, active power, apparent power and reactive power. Furthermore, it measures power factor and phase angle. The I/30 function helps users preset the required current at a reduced level. The system also includes thermal protection and a miniature circuit breaker.


Datasheet for Primary Current Injection Test System INGVAR

Download

User manual for Primary Current Injection Test System INGVAR

Download


Technology & Benefits

The Megger INGVAR uses primary current injection technology to test electrical protection systems under operating conditions. During testing, current flows through the primary circuit of the equipment. Therefore, engineers can check the complete current path and assess the response of protection devices. Moreover, the built-in measurement system displays current, voltage and timing values. It also calculates CT ratio, impedance, power factor and phase angle. In addition, the second measurement channel supports another current or voltage measurement. The I/30 function allows users to preset the required test current at a lower level. Consequently, it helps limit unnecessary heating before the main test. Furthermore, the fast-acting hold function captures short-duration readings. Its portable two-unit design also makes field testing easier. Thus, the INGVAR supports circuit breaker testing, relay testing, switchgear maintenance and substation commissioning.

Key Features

  • Primary current injection test system for electrical protection testing.
  • Maximum output current of up to 5000 A.
  • Control unit and current unit configuration.
  • Portable two-unit construction.
  • Approximately 20 kg weight per unit.
  • Unique I/30 reduced-current preset function.
  • Integrated digital measurement system.
  • Current, voltage and time measurement.
  • Current transformer turns ratio measurement.
  • Impedance, power and power factor calculation.
  • Phase angle measurement.
  • Second measurement channel for additional current or voltage.
  • Fast-acting hold function for short-duration readings.
  • Series and parallel current configurations.
  • Built-in thermal protection.
  • Suitable for medium-voltage substations and industrial environments.

Applications

  • Primary injection testing of protective relays.
  • Low-voltage circuit breaker testing.
  • Moulded case circuit breaker (MCCB) testing.
  • Air circuit breaker (ACB) testing.
  • Current transformer (CT) turns ratio testing.
  • Current transformer polarity testing.
  • Switchgear commissioning and maintenance.
  • Automatic recloser testing.
  • Sectionalizer testing.
  • Ground grid testing.
  • Electrical protection system verification.
  • High-current electrical testing.
  • Substation commissioning.
  • Industrial electrical maintenance.

Advantages

  • Provides high-current injection up to 5000 A.
  • Supports different electrical testing requirements.
  • Combines current injection and measurement functions.
  • Simplifies circuit breaker and protection relay testing.
  • Measures current transformer turns ratio and polarity.
  • Reduces test object heating through the I/30 function.
  • Captures short-duration readings through the hold function.
  • Supports additional measurements through the second channel.
  • Portable design simplifies transportation between testing locations.
  • Helps verify electrical protection system performance.
  • Suitable for field testing and industrial maintenance applications.

Adiradh Energy offers Primary Current Injection Test System INGVAR in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities