Adiradh offers the Megger ODEN Primary Current Injection Test System, designed for testing circuit breakers, protective relays, current transformers and electrical switchgear. This high-current injection system supports electrical commissioning, maintenance and performance testing in substations and industrial facilities. Moreover, it helps engineers verify circuit breaker operation by injecting high AC currents into the primary circuit. The system also supports current transformer (CT) testing, including turns ratio, polarity and phase angle measurements. Its modular design allows users to configure the system with one, two or three current units. Therefore, engineers can select a suitable configuration based on current and voltage requirements. Furthermore, its portable construction makes transportation and installation easier at different testing locations. The ODEN AT also provides integrated measurement functions for current, voltage, resistance, impedance and power. Consequently, it serves as a practical solution for primary injection testing across electrical substations, utilities and industrial power systems.

The Megger ODEN AT is a modular primary current injection test system developed for high-current electrical testing applications. It consists of a control unit and one, two or three current units. Moreover, users can select from three current unit types: S (Standard), X (Extra Output) and H (High Current). The X unit provides an additional 30/60 V output, while the H unit supports higher current requirements.The current units can operate in series or parallel configurations to achieve the required voltage or current. In addition, the control unit provides integrated measurement capabilities for current, voltage and time. It also calculates current transformer turns ratio, impedance, resistance, power, power factor and phase angle. Furthermore, its digital display and fast-acting HOLD function help capture short-duration measurements. The portable transport arrangement also supports movement between switchgear rooms and industrial testing locations.
Datasheet for Primary Current Injection Test System ODEN
Technical Guide for Primary Current Injection Test System ODEN
The Megger ODEN AT Primary Current Injection Test System uses a modular architecture consisting of a control unit and interchangeable current injection units. It is available with S, X and H current unit configurations. The system uses an AC current injection method to evaluate the performance of electrical protection equipment and primary circuits. Moreover, its integrated measurement section supports current transformer ratio testing, polarity verification and phase angle measurement. Its digital measurement interface displays readings and provides percentage values against nominal current and voltage. Furthermore, the fast-acting HOLD function captures short-duration readings when the selected stop condition occurs. The unique I/30 function allows current pre-setting at a lower current level before the main injection test. Consequently, it helps reduce unnecessary heating of the test object during current adjustment.
The Megger ODEN AT uses high-current AC injection technology to evaluate electrical equipment under operating-like current conditions. This method allows engineers to test the complete primary protection circuit rather than checking only individual secondary components. Moreover, primary injection testing helps verify the operation of current transformers, conductors, connections and protective relays within the test circuit.The integrated measurement system calculates important electrical parameters, including impedance, resistance, power factor and phase angle. In addition, the I/30 function supports low-current pre-setting before full current injection. The digital HOLD function captures short-duration measurements for review. Therefore, the ODEN AT supports circuit breaker commissioning, CT verification, ground grid testing and thermal testing. Its portable construction also makes field testing more convenient.
Adiradh Energy offers Primary Current Injection Test System ODEN in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities
![]()