Secondary injection relay test set T 1000 PLUS

Adiradh offers the Doble T 1000 PLUS Secondary Injection Relay Test Set for testing protective relays and electrical transducers. This multifunctional instrument supports commissioning, maintenance and diagnostic activities in substations and industrial power systems. Moreover, it combines AC current, AC voltage and DC voltage generation in one test unit. The instrument provides a maximum current output of 250 A with a 230 V supply configuration. In addition, it offers a maximum AC voltage output of 250 V and a DC voltage output of 300 V. Its frequency generator covers 15 Hz to 550 Hz, while the phase angle shifter allows adjustment from 0° to 360°. Furthermore, the built-in oscilloscope function displays current and voltage signals. Users can also store test settings and results in local memory. Therefore, the T 1000 PLUS supports a range of relay testing requirements through manual and semi-automatic operation.

Overview

The Doble T 1000 PLUS is a secondary injection test set designed to evaluate protective relays and transducers. It uses a main generator to produce AC current, AC voltage or DC voltage. Additionally, an independent auxiliary AC voltage generator provides a phase-shiftable output. A separate auxiliary DC voltage generator supplies power to the relay under test. The instrument supports a maximum current output of 250 A with a 230 V supply configuration. However, the available output depends on the selected current range and test conditions. Its AC voltage output reaches 250 V, while the DC voltage output reaches 300 V. Moreover, the frequency generator operates from 15 Hz to 550 Hz. The unit includes a digital timer, phase and frequency measurement, and two auxiliary contacts for autore closer testing. Furthermore, its USB interface transfers test results to a computer for review and analysis using compatible TDMS software.

About Product

The T 1000 PLUS uses secondary injection technology to assess the operating characteristics of electrical protection devices. Its main generator provides selectable AC current, AC voltage and DC voltage outputs. Moreover, the auxiliary AC voltage generator operates independently and supports phase angle adjustment between 0° and 360°. This function is useful when testing directional protection and phase-sensitive relay characteristics. The frequency generator supports frequency adjustment from 15 Hz to 550 Hz, with a stated adjustment resolution of 1 mHz. In addition, the digital timer measures relay operating times through make and break contact conditions. It supports both dry contacts and contacts under voltage. The instrument also provides current, voltage, phase and frequency measurement functions. Furthermore, its local memory stores up to 10 test settings and 500 test results. Users can transfer these records to a computer through the USB interface and analyse them with TDMS software.

Technology & Benefits

The T 1000 PLUS combines programmable signal generation, electrical measurement and relay timing functions. Its microprocessor-controlled system allows users to configure test parameters through the graphical LCD display and multi-function control knob. Moreover, the phase angle shifter adjusts the auxiliary AC voltage output relative to the main current or voltage. This supports testing of directional and phase-sensitive relays. The variable frequency function also allows users to examine relay response at different frequencies. In addition, the digital timer records relay operating times and supports automatic reclosing tests. Two auxiliary contacts provide connections for autore closer testing. The oscilloscope function helps technicians observe current and voltage signals during testing. Furthermore, local memory stores test settings and results for later use. The USB interface supports data transfer to a computer, where compatible TDMS software can record, display and analyse test results. Consequently, the instrument supports structured relay testing and documentation.

Key Features

  • Multifunctional secondary injection relay test set
  • Designed for testing protective relays and transducers
  • Maximum AC current output: 250 A with 230 V supply configuration
  • Maximum AC voltage output: 250 V
  • Maximum DC voltage output: 300 V
  • Frequency generator range: 15 Hz to 550 Hz
  • Frequency adjustment resolution: 1 mHz
  • Auxiliary AC voltage output with phase angle adjustment
  • Phase angle adjustment range: 0° to 360°
  • Separate auxiliary DC voltage generator for relay power
  • Oscilloscope function for current and voltage signals
  • Digital timer with automatic start and stop
  • Two auxiliary contacts for autore closer testing
  • Graphical LCD display and microprocessor control
  • Stores up to 10 test settings and 500 test results
  • USB interface for computer connectivity
  • Compatible with TDMS test and data management software
  • Synchronisation capability with multiple T 1000 PLUS test sets

Applications

  • Secondary injection testing of protective relays
  • Distribution relay testing
  • Overcurrent and earth-fault relay testing
  • Distance relay testing
  • Under-voltage and over-voltage relay testing
  • Directional power relay testing
  • Frequency relay testing
  • Negative sequence overcurrent relay testing
  • Phase sequence voltage relay testing
  • Automatic reclosing relay testing
  • Synchronising device testing
  • Motor protection relay testing
  • Thermal relay testing
  • Power factor relay testing
  • Voltage balance relay testing
  • Ground detector relay testing
  • Commissioning and maintenance of electrical protection systems

Advantages

  • Combines current and voltage generation in one test instrument.
  • Supports different protective relay testing requirements.
  • Provides adjustable frequency and phase angle settings.
  • Auxiliary DC output supplies power to the relay under test.
  • Digital timing supports relay operating-time measurement.
  • Two auxiliary contacts support autore closer testing.
  • Oscilloscope function helps users observe electrical signals.
  • Local memory stores test settings and results.
  • USB connectivity supports computer-based result management.
  • Manual and semi-automatic operation supports different testing procedures.
  • Compact design supports field testing and maintenance activities.

Adiradh Energy offers Secondary injection relay test set T 1000 PLUS in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities