Product Details

Home | Product Details

Secondary injection relay test set TD 1000 PLUS

Adiradh offers the Doble TD 1000 PLUS Secondary Injection Relay Test Set for testing protective relays and transducers in electrical power systems. This test set supports commissioning, maintenance and diagnostic work on different types of protection relays. Moreover, it features two current outputs, which allow users to test differential relay characteristics as well as relay pick-up current. The instrument also provides AC current, AC voltage and DC voltage generation. In addition, its frequency generator operates from 15 Hz to 550 Hz, supporting tests that require variable frequency signals. Furthermore, the built-in oscilloscope function displays current and voltage signals. Users can also save test settings and results in local memory. Therefore, the TD 1000 PLUS provides several relay testing functions in one instrument. Its USB interface supports data transfer to a computer for further review and reporting.

Overview

The Doble TD 1000 PLUS is a multifunction secondary injection test set designed for protective relay testing. It combines current and voltage generation with measurement and signal display functions. Moreover, its two independent current outputs support differential relay testing. This feature helps users examine differential relay characteristics beyond basic pick-up current checks. The instrument provides a maximum current output of 250 A, a maximum AC voltage output of 250 V and a maximum DC voltage output of 300 V. In addition, the frequency generator covers a range from 15 Hz to 550 Hz. A phase angle shifter allows phase adjustment during testing. The unit also includes a battery simulator with an output range of 20 V to 260 V DC.  The microprocessor-controlled system stores test settings and results in local memory. Consequently, it supports both field testing and test documentation.


Datasheet for Secondary injection relay test set TD 1000 PLUS

Download


About Product

The TD 1000 PLUS is a secondary injection relay testing instrument used to assess the operating characteristics of electrical protection relays. It includes a main generator and auxiliary outputs for producing test current and voltage signals. Moreover, the two current outputs allow testing of differential protection characteristics. Its frequency generation function covers 15 Hz to 550 Hz. In addition, the phase angle shifter provides control over the phase relationship between the generated signals. This is useful when testing directional and other phase-sensitive protection functions. The built-in battery simulator supplies DC voltage to the relay under test. Furthermore, the oscilloscope function displays current and voltage waveforms. The instrument also features a graphical display, microprocessor control and USB connectivity. Test settings can be stored and recalled from local memory. Therefore, technicians can perform manual and semi-automatic relay tests without requiring continuous computer connection.

Technology & Benefits

The TD 1000 PLUS uses controlled electrical signal generation to support secondary injection testing of protection relays. Its two current outputs are a key feature because they allow users to apply separate current signals during differential relay tests. Moreover, the frequency generator provides adjustable signals from 15 Hz to 550 Hz. This supports testing that requires frequency variation, including second-harmonic restraint characteristics of differential relays. The phase angle shifter also helps users adjust the relationship between current and voltage signals. In addition, the battery simulator provides DC supply to the relay under test. Furthermore, the instrument stores test settings and results in its internal memory. Users can transfer these records to a computer through the USB interface using compatible TDMS software. As a result, the test set supports relay evaluation, result review and documentation in commissioning and maintenance work.

Key Features

  • Two current outputs for differential relay testing
  • Maximum current output: 250 A
  • Maximum AC voltage output: 250 V
  • Maximum DC voltage output: 300 V
  • Frequency generator range: 15 Hz to 550 Hz
  • Phase angle shifter with adjustable phase control
  • Battery simulator: 20 V to 260 V DC
  • Oscilloscope function for current and voltage signals
  • Convertible current and voltage generator
  • Microprocessor-controlled operation
  • Graphical display for test settings and measurements
  • Local memory for storing test settings and results
  • USB interface for computer data transfer
  • Two auxiliary contacts for autorecloser testing
  • Supports manual and semi-automatic testing

Applications

  • Secondary injection testing of protective relays
  • Differential relay characteristic testing
  • Distribution relay testing
  • Smart grid relay testing
  • Single-phase relay testing
  • High-burden relay testing
  • Distance relay testing
  • Overcurrent and earth-fault relay testing
  • Under-voltage and over-voltage relay testing
  • Directional power relay testing
  • Frequency relay testing
  • Automatic reclosing relay testing
  • Synchronising device testing
  • Motor protection relay testing
  • Electrical protection system commissioning and maintenance

Advantages

  • Tests different protective relay types with one instrument.
  • Two current outputs support differential relay characteristic testing.
  • Adjustable frequency supports specialised relay test requirements.
  • Phase angle control assists testing of directional protection functions.
  • The battery simulator supplies DC voltage to the relay under test.
  • The oscilloscope function helps users observe electrical signals.
  • Local memory allows test settings and results to be stored.
  • USB connectivity supports transfer of test records to a computer.
  • Manual and semi-automatic operation supports different testing needs.
  • Suitable for commissioning and maintenance teams working with electrical protection systems.

Adiradh Energy offers Secondary injection relay test set TD 1000 PLUS in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities