Adiradh offers the AC Vacuum Interrupter Test Set 640-0.4P from Phenix Technologies for testing vacuum interrupters in medium-voltage circuit breakers and electrical switchgear. It generates AC test voltage up to 40 kVAC with a maximum output current of 10 mA. Therefore, it helps check the insulation strength of vacuum bottles. Moreover, it supports AC dielectric testing of suitable electrical equipment. In addition, its single-piece design makes it easy to move between test locations. The digital voltage and current meters also help operators check test readings. Furthermore, the manual voltage control allows easy output adjustment. For safe operation, the unit includes a Zero Start interlock, Emergency Off button and adjustable overload protection. As a result, electrical maintenance teams can use the 640-0.4P for vacuum interrupter testing in field and laboratory settings. Thus, it supports routine testing and maintenance of electrical switchgear.

The Phenix Technologies 640-0.4P is a portable AC Vacuum Interrupter Test Set with an output of up to 40 kVAC. It is mainly used to test vacuum bottles in medium-voltage circuit breakers. Moreover, it supports other suitable AC dielectric tests. The equipment provides a maximum output current of 10 mA. Therefore, it can check the insulation strength of vacuum interrupters within its rated capacity. In addition, its AC output supports high-voltage testing of suitable electrical equipment.
The digital meters display voltage and current readings during operation. As a result, operators can monitor the test values with ease. Moreover, manual voltage control allows them to adjust the output as required. The Zero Start interlock helps prevent output activation from an incorrect starting position. Furthermore, the adjustable overload circuit helps protect the equipment against excess current. The unit also uses a single-phase power supply with 50/60 Hz input frequency. Consequently, it is suitable for electrical testing labs, maintenance teams and field testing work.
Brochure for AC Vacuum Interrupter Test Set 640-0.4P
The AC Vacuum Interrupter Test Set 640-0.4P uses a high-voltage AC transformer to generate the voltage needed for vacuum interrupter testing. It provides an adjustable output of 0–40 kVAC with a maximum current of 10 mA. Moreover, a digital voltmeter and ammeter display the test readings. The high-voltage output uses a toroid connection with an output lead. Therefore, operators can connect the unit to the test setup as required.
The manual voltage control allows operators to raise or lower the applied voltage. In addition, the Guard mode helps improve current measurement accuracy. The Zero Start interlock controls the initial output condition. Furthermore, an adjustable overload circuit helps protect the equipment during abnormal loading. For added safety, an Emergency Off button allows quick shutdown. The unit also includes an external interlock provision. Finally, its cable storage space helps keep the test leads organised during transport and storage.
The 640-0.4P uses AC dielectric testing technology to check the insulation strength of vacuum interrupters. During testing, it applies a controlled AC voltage across the test object. Consequently, operators can check whether the vacuum bottle can withstand the required test voltage. The equipment generates up to 40 kVAC with a maximum output current of 10 mA. Moreover, digital meters display voltage and current during the test. Therefore, operators can monitor the electrical readings throughout the process.
The manual control allows operators to adjust the test voltage as needed. In addition, the Zero Start interlock helps prevent accidental output activation. The adjustable overload circuit also helps protect the equipment against excess current. Furthermore, the Emergency Off button provides a quick way to stop the test. Guard mode, meanwhile, helps improve current measurement accuracy. The portable, single-piece design also makes transport easier. As a result, testing teams can move the equipment between suitable test locations. Thus, the 640-0.4P supports field testing, maintenance and laboratory work.
Adiradh Energy offers AC Vacuum Interrupter Test Set 640-0.4P in India; Hyderabad; Visakhapatnam; Vijayawada; Chennai; Puducherry; Trichy; Coimbatore; Hosur; Bangalore; Hubli; Mysore; Cochin; Kolkata; Pune; Goa; Mumbai; Thane; Kanpur; Jaipur; Nagpur; Delhi; Noida; Gurugam; Bhopal; Vadodara; Ahmedabad; Chandigarh; Chandigarh; Tata Nagar; Raipur; Rudrapur; Durgapur; Kharagpur; Raigarh; Bhilai; Angul; Haldia; Jabalpur; Indore; Jamshedpur; Rajahmundry; Bokaro Steel City; Salem; Kochi; Rourkela; Ahmedabad ;Jamnagar; Bharuch; Sri City; Nashik; Haridwar; Mathura; Aurangabad; Bhubaneswar and other cities
![]()
2025 - Industry. All Rights Reserved.